Main features & overview

02 tri

Overview

Description

  • Temperature limits:
    - 200 ... +800°C
  • Tolerance: UNI 7937, IEC 751 standards:
    ± 0.15°C at 0°C for class A (1/2 DIN)
    ± 0.30°C at 0°C for class B (1 DIN)
    ± 0.10°C at 0°C for 1/3 DIN class
  • Insulation: > 100 MOhm for voltage values from 10 to 100 Vcc
  • PT100 wire-wound resistance thermometer
  • Application versatility

Main features & overview

01 TR7M

Overview

Description

  • Temperature limits:
    -200 ... +600°C
  • Tolerance: UNI 7937, IEC 751 standards:
    ± 0.15°C at 0°C for class A (1/2 DIN)
    ± 0.30°C at 0°C for class B (1 DIN)
    ± 0.10°C at 0°C for 1/3 DIN class
  • Insulation: Mineral Oxide (MgO)
  • PT100 wire-wound resistance thermometer
  • Min. size: 100mm including connector

Main features & overview

03 TRM

Overview

Description

  • Temperature limits: - 40 ... + 400° C
  • Tolerance: UNI 7937, IEC 751 standards:
    ± 0.15° C a 0° C for class A (1/2 DIN)
    ± 0.30° C a 0° C for class B (1 DIN)
    ± 0.10° C a 0° C for 1/3 DIN class
  • Compact mineral insulated (MgO) resistance thermometer element (Pt100 at 0°C) and continuous metal sheath

Main features & overview

01 TR1

Overview

Description

  • Temperature limits: -40 ... +250°C
    (see table for type of extension cable used)
  • Tolerance: UNI 7937, IEC 751 standards:
    ± 0.15°C at 0°C for class A (1/2 DIN)
    ± 0.30°C at 0°C for class B (1 DIN)
  • PT100 at 0°C sensor
  • Application versatility

Main features & overview

03 TR5 TR5N

Overview

Description

  • Temperature limits:
    -40 ... +250°C
    (see table for type of extension cable used)
  • Tolerance: UNI 7937, IEC 751 standards:
    ± 0.15°C at 0°C for class A (1/2 DIN)
    ± 0.30°C at 0°C for class B (1 DIN)
  • PT100 at 0°C sensor
  • Stainless steel AISI 303 sheath
  • Adjustment spring thread connection: 8mm diameter, 300mm length

Main features & overview

02 TR1M

Overview

Description

  • Temperature limits:
    - 200 ... +600°C
  • Tolerance: UNI 7937, IEC 751 standards:
    ± 0.15°C at 0°C for class A (1/2 DIN)
    ± 0.30°C at 0°C for class B (1 DIN)
    ± 0.10°C at 0°C for 1/3 DIN class
  • Compact mineral insulated (MgO) resistance thermometer element (PT100 at 0°C) and continuous metal sheath
  • Application versatility

Main features & overview

05 TRD

Overview

Description

  • Max. temperature limit:
    - 40 ... + 600° C
  • Reference tolerances:
    UNI 7937, IEC 751:
    ± 0,15°C a 0°C per 1/2 DIN (class A)
    ± 0,30°C a 0°C per 1 DIN (class B)
    ± 0,10°C a 0°C per 1/3 DIN
  • Sensitive element with MgO isolation Pt100 at 0°C

Main features & overview

04 TRD

Overview

Description

  • Temperature limits: -40 ... +150°C
  • Tolerance: UNI 7937, IEC 751 standards:
    ± 0.15°C at 0°C for class A (1/2 DIN)
    ± 0.30°C at 0°C for class B (1 DIN)
    ± 0.10°C at 0°C for 1/3 DIN class
  • Tinned copper conductors with silicon rubber insulation
  • PT100 wire-wound resistance thermometer
  • Extension cable with 4 tinned copper conductors, silicon rubber primary insulation with Mylar Aluminium screen, silicone rubber outside insulation.
  • Free wire termination
  • Transition with 12 mm external diameter with circular tightned folded seam (double)
  • Specific use for immersion in concrete

Main features & overview

03 TR6M

Overview

Description

  • Temperature Limits:
    -200 ... +600° C
  • Tolerance: UNI 7937, IEC 751 standards:
    ± 0.15° C a 0° C for class A (1/2 DIN)
    ± 0.30° C a 0° C for class B (1 DIN)
    ± 0.10° C a 0° C for 1/3 DIN class
  • Compact mineral insulated (MgO) resistance thermometer element (Pt100 at 0°C) and continuous metal sheath
  • Application versatility

Main features & overview

01 TR2 AR2

Overview

Description

  • Temperature Limits:
    -200 ... +600° C
  • Tollerance: UNI 7937, IEC 751 standards:
    ± 0.15° C a 0° C for class A (1/2 DIN)
    ± 0.30° C a 0° C for class B (1 DIN)
    ± 0.10° C a 0° C for 1/3 DIN class
  • Insulation: > 100 MOhm for voltage values from 10 to 100 Vcc.
  • PT100 wire-wound resistance thermometer
  • Mineral insulated interchangeable insert
  • Application versatility

Main features & overview

03 TR6M

Overview

Description

  • 4...20mA Transmitter
  • Amplified output signal
  • Temperature limits: - 200 ... + 600° C
  • Tolerance: UNI 7937, IEC 751 standards:
    ± 0.15° C a 0° C for class A (1/2 DIN)
    ± 0.30° C a 0° C for class B (1 DIN)
    ± 0.10° C a 0° C for 1/3 DIN class
  • Compact mineral insulated (MgO) resistance thermometer element (Pt100 at 0°C) and continuous metal sheath
  • Application versatility

Main features & overview

01 TR2 AR2

Overview

Amplified output with interchangeable MgO insert

Description

  • Amplified output signal
  • Temperature limits:
    -200 ... +600°C
  • Tolerance: UNI 7937, IEC 751 standards:
    ± 0.15°C at 0°C for class A (1/2 DIN)
    ± 0.30°C at 0°C for class B (1 DIN)
    ± 0.10°C at 0°C for 1/3 DIN class
  • Insulation: > 100 MOhm for voltage values from 10 to 100 Vcc o
  • PT100 wire-wound resistance thermometer
  • Mineral insulated interchangeable insert
  • Application versatility

Main features & overview

02 TR6 AR6

Overview

Description

  • Temperature limits: - 40 ... + 300° C
  • Tolerance: UNI 7937, IEC 751 standards:
    ± 0.15° C at 0° C for class A (1/2 DIN)
    ± 0.30° C at 0° C for class B (1 DIN)
    ± 0.10° C at 0° C for 1/3 DIN class
  • Ceramic insulation of sensor, PT100 at 0° C
  • Application versatility

Main features & overview

04 tra

Overview

Description

  • Max. temperature limit:
    - 40 ... + 90° C
  • Reference tolerances:
    UNI standards: Norme UNI 7937, IEC 751:
    ± 0,15°C a 0°C per 1/2 DIN (class A)
    ± 0,30°C a 0°C per 1 DIN (class B)
    ± 0,10°C a 0°C per 1/3 DIN
  • Sensitive element with ceramic isolators Pt100 at 0°C
  • Fiberglass-reinforced polyester case, dimensions:
    56x75x110mm

Main features & overview

02 TR6 AR6

Overview

Description

  • Transmitter 4...20mA
  • Amplified output signal
  • Temperature limits: - 40 ... + 300° C
  • Tolerance: UNI 7937, IEC 751 standards:
    ± 0.15° C a 0° C for class A (1/2 DIN)
    ± 0.30° C a 0° C for class B (1 DIN)
    ± 0.10° C a 0° C for 1/3 DIN class
  • Ceramic insulation of sensor, PT100 at 0° C
  • Application versatility

Main features & overview

05 acc

Overview

  • Extension and compensation cables for Thermocouples
  • Protective sheathings
  • Sliding compression fittings
  • Connection heads
  • 4-20ma signal amplifiers
  • Adapter for 4-20ma signal amplifiers
  • Display
  • IP67 remote temperature inputs on CANpen fieldbus
  • Connectors

Description

  • Extension and compensation cables for Thermocouples
  • Protective sheathings
  • Sliding compression fittings
  • Connection heads
  • 4-20ma signal amplifiers
  • Adapter for 4-20ma signal amplifiers
  • Display
  • IP67 remote temperature inputs on CANpen fieldbus
  • Connectors
FaLang translation system by Faboba