Main features & overview

05 cu

Overview

The CU range of load cells are designed for the measurement of static or dynamic loads in compression.

All the transducers are calibrated as load cells in units of mass (Kg).

The CU series is supplied for nominal loads from 50 Kg to 1 T.

This model has an IP67 protection degree so it can be used in aggressive atmospheres often found in the chemical industries.

The transducer body is machined from a single piece of stainless steel with no welding.

This means that it is highly resistant to mechanical shock and vibration.

The compact size means that these cells can be placed in positions that are difficult to acess and where little space is available.

Description

  • Range of measurement: from 50 to 1,000 Kg
  • Accuracy class: 0.2%
  • All stainless steel construction
  • Corrosion resistant
  • Grade of protection: IP67 (DIN 40050)
  • Compact size

Main features & overview

03 cm1

Overview

CM series load cells are strain gauge transducers used to measure loads in static and dynamic applications, in compression, with high accuracy.

They are machined from a single block of metal, so the primary sensing element, the mountings and the case contain no welds allowing smaller dimensions and an enhanced grade of protection. The configuration of the point of measurement, with 8 strain gauges, reduces errors caused by imperfect applications of the load.

Typical applications of load cells connected in parallel are: silos, hoppers, large weighing platforms.

The stainless steel construction is suitable for use in aggressive environments in the chemical and petrochemical industries.

Description

  • Range of measurement: from 100 to 50,000 Kg
  • Accuracy class: 0.2%
  • All stainless steel construction
  • Corrosion resistant
  • Internally generated calibration signal
  • Grade of protection: IP67 (DIN 40050)

Main features & overview

01 AMxWEB

Overview

The AM force transducers series have been designed to measure static and dynamic compression forces.

They are particularly suitable for monitoring pounding operations in compression which require a rugged transducer, insensitive to high resonance frequencies caused by non-homogeneous leads in dynamic sequences.

The accuracy and the stability are not affected by continuous cycling under harsh conditions even with dynamic loads.

The small size of the AM force transducers makes them ideal for retrofitting in existing equipment.

Description

  • Range of measurement: from 5 to 20 kN
  • Accuracy class: 1%
  • All stainless steel construction
  • Corrosion resistant
  • Grade of protection: IP65 (DIN 40050)
  • Small size

Main features & overview

02 cc

Overview

  • Range of measurement: from 750 to 1,500 kN
  • Accuracy class: 1%
  • Internally generated calibration signal
  • All stainless steel construction
  • Corrosion resistant
  • Grade of protection: IP65 (DIN 40050)

Description

The CC force transducers have been designed for use in the plastics industry where it is required to measure the reaction force to the extrusion pressure that is present on the casing of the gearbox along the axis of the extruder screw.

These models, fitted in contact with the thrust bearings, measure a force whose valve, after suitable correction, is equal to extrusion pressure multiplied by the screw area.

The CC cylindrical force transducers are all stainless steel construction and configured in such a way that the body, airtight welded, acts also as the case, making a unit that is smaller than the CT series.

The connector in the shank is on the same axis as the transducer, which in some cases alows easier installation.

Main features & overview

04 ct

Overview

The CT series force transducers, have been specially designed for use in polymer processing in applications where it is required to measure the reaction force produced by the extru-sion pressure on the gearbox along the axis of the screw.

They measure a force whose value is indicative of the extrusion pressure over the area of the screw.

The CT series force transducers can also be used in all other applications where it is required to measure the forces on shafts or columns and in any application where the geometry demands a toroidal form load cell.

Description

  • Range of measurement: from 100 to 3000 kN
  • Accuracy class: 0.5%
  • Elastic element in stainless steel
  • Corrosion resistant
  • Internally generated calibration signal
  • Grade of protection: IP65 (DIN 40050)

Main features & overview

05 tu

Overview

The TU range of load cells are designed for the measurement of static or dynamic loads in compression or traction.

All the transducers are calibrated as load cells in units of mass (Kg).

The TU series is supplied for nominal loads from 50 Kg to 1 T.

This model has an IP67 protection degree so it can be used in aggressive atmospheres often found in the chemical industries.

The transducer body is machined from a single piece of stainless steel with no welding.

This means that it is highly resistant to mechanical shock and vibration.

The compact size means that these cells can be placed in positions that are difficult to acess and where little space is available.

Description

  • Range of measurement: from 50 to 1,000 Kg
  • Accuracy class: 0.2%
  • All stainless steel construction
  • Corrosion resistant
  • Grade of protection: IP67 (DIN 40050)
  • Compact size

Main features & overview

03 tc

Overview

TC series load cells are strain gauge transducers used to measure loads in static and dynamic applications, in tension and compression, with high accuracy (industrial weighing, laboratory testing, automation, etc).

The TC series is machined from a single block of metal, so the primary sensing element, the mountings and the case contain no welds allowing smaller dimensions and an enhanced grade of protection.

The configuration of the point of measurement, with 8 strain gauges, reduces errors caused by imperfect application of the load.

Typical applications of load cells connected in parallel are: silos, hoppers, large weighing platforms, and with suitable accessories, suspended loads.

The stainless steel construction is suitable for use in aggressive environments in the chemical and petrochemical industries.

Description

  • Range of measurement: from100 to 20,000 Kg
  • Accuracy class: 0.2%
  • All stainless steel construction
  • Corrosion resistant
  • Internally generated calibration signal
  • Grade of protection: IP67 (DIN 40050)

Main features & overview

04 TH MH dxicon

Overview

The TH series force transducers are ideal for systems that measure tension or compression force in industrial applications, where accuracy and reliability are important, even in harsh environments.

The disposition of the (8) strain gauges of the measurement bridges uses the deformation produced by the shear force of the applied load.

It is thus possible to make accurate force transducers that are rugged and insensitive to lateral loads.

The transducer is machined from a solid block of stainless steel and contains no welds or joints.

The electrical circuit is protected by sealed formed stainless steel plates.

Description

  • Range of measurement: from 10 to 100 kN
  • Accuracy class: 0.2%
  • All stainless steel construction
  • Corrosion resistant
  • Internally generated calibration signal
  • Grade of protection: IP65 (DIN 40050)

Main features & overview

01 dlc

Overview

Pancake like diaphragm load cell designed for the use in Fully electric Injection Molding Machines.

The Flat-Body design allows for easy integration into the injection unit without adding to the machine length.

Available with standardized mV/V output or an EEPROMModule to allow for higher mV/V-Output for better signal/noise ratio (to be used with special VDA-Amplfier).

High-grade steel for endless cycles and optional amplifer necessary.

Description

Main features

  • FLAT-body design
  • Good linearity
  • Designed integrate into machine
  • With EEPROM for sensitivity detection (option)

Main features & overview

02 dlca

Overview

Pancake like diaphragm load cell designed for the use in Fully electric Injection Molding Machines.

The Flat-Body design allows for easy integration into the injection unit without adding to the machine length.

Description

Main features

  • FLAT-body design
  • Good linearity
  • Designed integrate into machine

Main features & overview

01 sb

Overview

The principle of measurement of the SH series load cells is the deformation caused by the shear generated by the applied load.

The result is a transducer that is extremely rigid both for the measured load and of lateral or transverse loads which have little effect on it.

The high degree of accuracy, good level of thermal compensation, the grade of protection make the SH series load cells safe for use in the most severe conditions.

Description

  • Range of measurement: from 500 to 10,000 Kg
  • Accuracy class: D1 (OIML IR60)
  • All stainless steel construction
  • Corrosion resistant
  • Insensitive to lateral loads
  • Grade of protection: IP66 (DIN 40050)

Main features & overview

02 sh

Overview

The principle of measurement of the SH series load cells is the deformation caused by the shear generated by the applied load.

The result is a transducer that is extremely rigid both for the measured load and of lateral or transverse loads which have little effect on it.

The high degree of accuracy, good level of thermal compensation, the grade of protection make the SH series load cells safe for use in the most severe conditions.

Description

  • Range of measurement: from 500 to 10,000 Kg
  • Accuracy class: D1 (OIML IR60)
  • All stainless steel construction
  • Corrosion resistant
  • Insensitive to lateral loads
  • Grade of protection: IP66 (DIN 40050)

Main features & overview

01 cb

Overview

  • Range of measurement: from 20 to 200 Kg
  • Accuracy class: C (OIML IR60)
  • All stainless steel construction
  • Corrosion resistant
  • Grade of protection: IP67 (DIN 40050)

Description

CB series load cells are designed for trouble free application in industrial environments.

The cell body and the protective bellows of the strain gauge are in corrosion resistant stainless steel and the bellows are welded using microplasma torch.

CB load cells are supplied in three grades of accuracy and characteristics.

The 1000 division is the most economical and suitable for most applications.

The 2000 division version has a good price/performance ratio.

The 3000 division is available if higher accuracy is required.

CB load cells are used in particularly hostile enviroments in the food, petrochemical and pharmaceutical industries and in all applications that demand components in stainless steel and IP67 grade of protection.

Main features & overview

02 tr

Overview

TR series force transducers are used to measure the tension that plastic films or tapes exert on the guide rollers of the machinery used to coil them.

Mounted at the ends of a fixed or transmission shaft on the machine chassis, they perform the function of force sensors and bearing for the ends of the shaft.

They are used on both fixed and rotating shafts.

TR transducers are supplied with the adaptor flange for fixing, with 4 M6 screws or with one central M10 or M12 screw.

Description

  • Range of measurement: from 100N to 2kN
  • Accuracy class: 0.5%
  • Corrosion resistant
  • Internally generated calibration signal
  • Orientation of the axis of maximum sensitivity for 35° independently from
  • the position of the fixing holes
  • Grade of protection: IP65 (DIN 40050)
  • Integrated protection against overloads

Main features & overview

02 cir d

Overview

  • Linearity error < 0.02% FSO
  • Voltage or current output
  • Low thermal drift < 0.01% FSO/°C
  • Compact size

Description

The CIR voltage or current amplifiers have been designed to enable the user to adapt non-amplified strain gauge transducers (load cells, pressure transducers) to acquisition systems, PLC, instrumentation with high level inputs.

The availability of the output in voltage or current enables the signal to be carried over long distances or used in intelligent automation systems

Main features & overview

01 cir

Overview

  • Linearity error < 0.02% FSO
  • Voltage or current output
  • Low thermal drift < 0.01% FSO/°C
  • Compact size

Description

The CIR voltage or current amplifiers have been designed to enable the user to adapt non-amplified strain gauge transducers (load cells, pressure transducers) to acquisition systems, PLC, instrumentation with high level inputs.

The availability of the output in voltage or current enables the signal to be carried over long distances or used in intelligent automation systems

FaLang translation system by Faboba